Jakubczyk, Michał
ORCID: https://orcid.org/0000-0002-0006-6769, Rencz, Fanni
ORCID: https://orcid.org/0000-0001-9674-620X and Rand, Kim
ORCID: https://orcid.org/0000-0001-7692-4099
(2026)
A consistency criterion for EQ-5D-5L bolt-on valuation.
European Journal of Health Economics, 2026
.
DOI 10.1007/s10198-026-02009-z
|
PDF
- Requires a PDF viewer such as GSview, Xpdf or Adobe Acrobat Reader
1MB |
Official URL: https://doi.org/10.1007/s10198-026-02009-z
Abstract
Objective EuroQol is developing the EQ-5D Bolt-on Toolbox, an experimental set of bolt-ons designed to improve the sensitivity of EQ-5D-5L in specific populations. For use in cost-utility analyses, EQ-5D-5L+bolt-on value sets should be consistent with EQ-5D-5L value sets. This study proposes a method to define and maintain such consistency and examines its properties. Methods We developed a novel contraction method that defines consistency using the distribution of disutilities in measurement data and estimates a contraction parameter from the conditional distribution of bolt-on levels given the core EQ-5D-5L profile to account for information overlap. The method was tested for nine bolt-ons: breathing, cognition, hearing, self-confidence, skin irritation, sleep, social relationships, tiredness, and vision. We used general-population samples from 14 countries, with 10,395–42,206 observations per bolt-on, and patient samples from six disease areas, with 312–2,486 observations. Core-dimension disutilities were based on the UK EQ-5D-5L value set, and bolt-on disutilities were taken from published studies. Associations of the contraction parameter with bolt-on disutilities and core-dimension correlations were assessed using linear regression. Results Achieving consistency required contraction factors ranging from 0.871 for breathing to 0.989 for sleep. Stronger contraction was required for bolt-ons with larger disutilities and for those more strongly correlated with the core dimensions, although only the former association was statistically significant. Conclusion The contraction method aligns EQ-5D-5L+bolt-on value sets with EQ-5D-5L value sets, reducing potential double counting while preserving the increased sensitivity provided by bolt-ons.
| Item Type: | Article |
|---|---|
| Uncontrolled Keywords: | Consistency; Valuation; EQ-5D-5L; Bolt-on; EQ-5D Bolt-on Toolbox; |
| JEL classification: | C18 - Methodological Issues: General D61 - Allocative Efficiency; Cost-Benefit Analysis D63 - Equity, Justice, Inequality, and Other Normative Criteria and Measurement I10 - Health: General |
| Divisions: | Institute of Social and Political Sciences |
| Subjects: | Social welfare, insurance, health care |
| Funders: | EuroQol Research Foundation |
| Projects: | 2009-RA |
| DOI: | 10.1007/s10198-026-02009-z |
| ID Code: | 13426 |
| Deposited By: | MTMT SWORD |
| Deposited On: | 30 Oct 2026 11:30 |
| Last Modified: | 30 Oct 2026 11:30 |
Repository Staff Only: item control page